NI Hardware

Venetian blind control using motor continuous

Hello everyone... im from Malaysia IM want to know how to create VI which I controlled motor continuous... motor continuous control the shutter according to the density of lux... It will open angle by angle to synchronize with the lux and time densit

OR USB6008 + NiDaqMxBase + Linux input analog simultaneous

Hello! My configuration: OR USB6008 NiDaqMxBase Linux OpenSUSE 11.0 on Toshiba NB200 netbook I need to measure 4-channel AI 5 times per second. Yes: create AI0... AI3 = DAQmxBaseCreateAIVoltageChan (taskHandle, chan, "", DAQmx_Val_RSE, min, max, DAQm

Impossible to install 2 mseries Renault on XP PC

With Windows XP PC I can install either our PCI-6229 or our map of pci PCI-6289 and everything works fine, but when I put both of them in windows keeps trying to install it and can't seem to say the the 6289 6229. If I start a Setup with no driver in

measure mV cDAQ NI 9205

Hi guys I'm trying to measure a voltage (in millivolts at the ends of a thermocouple) using NI9205. However, when I tried to enter a minimum and a maximum value of the voltage the virtual channel to measure the voltage, I am unable to power supply of

How to read multiple channels based on the external clock

Hello Normal 0 false false false MicrosoftInternetExplorer4 / * Style Definitions * / table. MsoNormalTable {mso-style-name: "Table Normal" "; mso-knew-rowband-size: 0; mso-knew-colband-size: 0; mso-style - noshow:yes; mso-style-parent:" ";" mso-padd

Control of heating/cooling (Peltier) in DC (not PWM)

I am trying to set up a system to control heater / cooler Peltier element like this: +/-5V @ 1. 25A With the help of current continuous (through a PID controller), not a PWM. I am considering using CRIO or PXI platforms. -The CRIO, I found the motion

Writing DAQmx invoke node leads to a runtime error (R6025 - pure virtual function call)

I have a request in which a Subvi DAQmx writing calls calling node (shift of writing and reading NumChans). When I launch LabVIEW and the main VI a first run, everything works fine. When I run a second time, LabVIEW crashes with a runtime to Scriptur

Build the application error

Hello When running an application in visual C stored under "C:\Program NIUninstaller Instruments\NI-DAQ\Examples\VisualC\Ai", I get a runtime error stating that "the application could not initialize properly (0xc0150002). Click OK to close the applic

Incorrect voltage to a channel with NI9205

Hello everyone I measure 10 tension of cell with a NI 9205 (differential mode, volt min. = 1, maximum voltage = 3). Everything works fine, until tensions are higher than 2.7 V. channel 17 (cell number 10), the voltage begins to decrease. All the othe

where is the function AI_VRead() defined, which is used in the AIonePoint.c file. ?

Hello I installed the Ni DAQ software for 6024E card. As I walked through the code examples in Visual C, I came across AIonePoint.c file where the AI_VRead() function has been used. But I could not find the function definition. I would like to know w

How to activate digital outport on USB6211?

Hello, I use a usb6211 with DAQmx8.9 and LabVIEW 8.6.1. The lines of dio ports do not appear in the menus of routing functions... How can I activate those ports? Thanks for any advice, Vincent

How to control the sequence of scanning channels in DAQmx

I have an application written for the traditional DAQ C API that I need to convert to use DAQmx drivers. The application uses the SCAN_Setup function to create a canal complex analysis sequence of taste effectively at different rates on each channel

NEITHER USB-6501 not recognized by the system

Hi all I wrote this simple application that writes and reads a SPI frame. My PC have Labview 8.5.1 and DAQmx 8.7.1 (the CD was provided with my unit NI USB-6501). Everything works fine. But now I need to distribute the application, and I need to run

DAQ_Clear for DAQmx

Hello? I'm working on the conversion of DAQ DAQmx. As we know that daq_clear can be worn in DAQmxStopTask/DAQmxClearTask in DAQmx. But the question is, is it possible to stop the task all loaded both in DAQmx? Code of DAQ_Clear. It stops at all the a

USB 6008 - how to display the two position linear pot (mm) and output (volts) in LabVIEW?

I have a USB-6008. I have a linear potentiometer attached to the USB DAQ. Now I can view the output voltage of pot in LabVIEW through the AI0 on USB DAQ channel. However, I would also like to be able to show the position of the stem of the linear pot

DAQ Assistant in labview7.0

Hello Recently, I bought a PCI - MIO - 16 - 4 to fit our labview7.0 DAQ. After installing the driver (from the CD), the card works fine with MAX and labview signalexpress. However, the default program is not at our request. So, I tried to schedule wi

What is the best way to run DAQ in larger system?

I have a relatively simple installation of the PXI hardware require software in real time to perform data acquisition and to provide feedback to the user.  Somewhere on the order of discrete outputs 150, 55 entered discrete, some analog, etc...  My q

Negative terminals on the terminal block

Hello, this is a really stupid question, but after using my card for the acquisition of data (NI DAQcard 6024E) with my connection block (SCC-68) more than one year with entries NRSE, I now need to connect differential inputs. However, the connection

How to control 2 motor epos using microcontroller 50/5

Hello. I did a program of integrated epos of labVIEW for control 1 motor epos. I make the program using the sub - vi from labVIEW epos data, but I don't know how to control 1 motor. Can anyone help me or tell me how to control 2 motors or wad is nece

a digital trigger point

I'm trying to convert "a digital trigger point" (an example of data acquisition for the E-series card) for one that runs on the series 621 x, which have similar I/O.  No joy.  The closest I come is one who clings both labview and my computer, which I