NI Hardware

Re-install LabVIEW after the reconfiguration of the IP address and computer name

I was working with LabVIEW 8.6. Recently, I reconfigured its name and the IP address of my desktop computer and rebooted the system (recommended once you change the IP address). LabVIEW8.6 has stopped working because soon, I restarted. Tried to unins

8105 PXI for PXI-8110 upgrade

We are to modernize a PXI-8105 to a PXI-8110. When fit us the processor module into the 1045 cardframe (3 years), we have no response from the monitor and no idea if the keyboard works either. If we put the PXI-8110 return in the 1045 cardframe we ju

PXI-6509 necessary connection block

Hello It s necessary to work this pxi-6509 is attached to the connection (i.e. SCB-100) via the cable block; or can be directly connected to the cable (i.e. HS-100-100-F)? Thank you

Problems of allocation of resources motherboard PCI with PXI controllers

I set up a test system to a PXI-PCIe8361 controller and a PXI-1042 chassis.  Several years ago, there are known problems with some motherboards on the assignment of the PCI resources.  I looked and could not find more old messages and lists of recomm

No laptop power when the ExpressCard-8360 card is connected

I can't turn on my laptop when the expresscard is connected. I use PXI - 8360 ExpressCard with my Dell Vostro 1000 (BIOS 2.6.2 Windows XP Professional Version 2002 SP 2) connected to the NI PXI-1033-NI PXI-6220 chassis in slot 2. I installed the driv

Conflict of the PXI-8461

Hi all I'll put up a PXI module which, like a BOX of cards in a chassis PXI-1042 (PXI-8461) by using a controller PX-8360. I also have a PCI CAN map at the back of the PC that I use. There seems to be a conflict - can someone help me please? Concerni

Combining MXI-4 x 665

Hello This is my setup: Master PXI chassis: -Holds PXI controller to slot 1 -18 sites -Several Modules PXI chassis slave: -NO PXI controller -18 sites -Several Modules However, here is my question: Can I combine the data transfer with synchronization

Fast analog generation ramps simultaneously

With the acquisition of data-mx, trying two fast and simultaneous output analog ramps.  I created the attached .vi and know that if I try just an exit ramp, my method works.  However, when I add the second a ramp channel generates a ramp and when it'

Is it possible to a floating voltage with the output box usb-6009?

Hello I was wondering if anyone knows how to a difference in voltage output 0 to 1 AO on the box USB-6009 DAQmx AO without reference to the ground.  Any help would be greatly appreciated. Thank you Bryan

Synchronized in my cDAQ-9172 multiple input signals?

I use NEITHER cDAQ-9172, and I currently have 20 signals from various sensors (acceleration, speed, power, etc.). How can ensure me that when I start my vi, all input data is saved from the exact same hour?

Setup of NOR-DAQmx 8.8 Error 1303

I recently bought NI USB-6211, who works with the software NOR-DAQmx 8.8. I have LabView 7.1 installed in my PC which remains compatible with NOR-DAQmx 8.8. Every time when I try to install the driver OR-DAQmx 8.8, you receive the following error mes

Data acquisition inherited Configuration MAX window

I have LabVIEW 7.1, and Max under the software it shows v8.8 NOR-DAQmx and v7.4.4 NOR-traditional DAQ. When I am developing devices and Interfaces, only from the devices listed OR-DAQmx ppears with the DAQ card (PCI-6221: "Dev1"). The VI I need to ru

Which is better: using the NI 9203 or USB Volt to differential entrance map

Dear all, I have 4 pressure transmitters, temperature transmitters 4 with output 0-10 v or 4-20 my. I have also 2 with output 4-20 flow meters my. I have two options: Is to get all the signals in my and link them to the C two modules NI 9203 or I can

Is the C API of DAQmx compatible cross-platform?

Given the same material of NOR and the last DAQmx software is installed. Would the same DAQmx associated with C source compiles and work on Windows, Linux and Mac OS X? I ask this, because I already produced an application of special measures using t

Programmatically change the sampling for AO / DO

Hello I'm doing some AO / DO with a few tips, PXI, including a series PXI-6221 Mr., I wonder if it is possible to progammatically change the sampling frequency at a certain point in time. After awhile my program between a low-maintenance lifestyle an

Modules to relay 'High tension' OR USB can be used to pass ultrasound

A researcher needs spend a single driver/sensor map ultrasonic transducers.  Ultrasonic excitation is pulse frequency reaching hundreds of volts.  OR devices such as USB-9481 are called 'high voltage' but are evaluated and only 250Vrms for 30 VDC swi

How to acquire encoder have z low A & amp; High B?

I'm working on Labview with NI USB-6259 8.5 and I have a quadratic encoder where Z is low and A - B are secondary, I realized that Labview can acquire A and B High or Low but not impulses for z is there a way to solve this problem? As matter of fact

Daqmx 8.7.1 with Vista installation issues

I try to install DaqMx 8.7.2 in my computer running Windows Vista. I want to install USB 6501. I installed in my computer LabVIew 7.1, 8.6 and Beta 2009 8.5.1. When I try to install Daqmx, instalation program shown in the following image. Is that wha

You can control a peltier with DAQPad-6015 chip?

Hey,. It is a simple enough question.  I was controlling a DC power supply with a labview code that I wrote.  Then my colleague told me that it was possible to control the chip peltier directly via the DAQPad.  Is this true?  If so, how I would contr