NI Products

Profile of Stimulus running of the door of entry/host

I would like to know if this is possible: Run a VeriStand project on one computer (the ' bridge') and run profiles of stimulus from another computer on the same subnet. I try to do that and specify IP address of gateway of the stimulus profile editor

Customized for the RT FIFO device details

Hello I have a few questions about the FIFO VeriStand in a custom device asyncrounous. I saw a post earlier where a - 1 to the function of reading of FIFO of RT for him to wait indefinitely for an item to enter the FIFO. This allows pseudo - synchron

Options configuration NOR in MatLab compiler

Hello I am compiling a .mdl in a .dll file. I followed the instructions OR on the way to link this (http://www.ni.com/white-paper/13066/en) and it works fine. I'm curious to know what options exist under "Code Generation-> NI Configuration-> addition

Rename a custom device

Hi all I made a custom device that perform some operations with the associated DAQ card. In the Solution Explorer system Veristand, to manage several boards, it is possible to add multiple instances of it. The name of each instance must match the ass

Compile the LabVIEW .vi for VXWorks .out file

Is it possible to use LabVIEW to compile a .vi in a .out to use file as a model of Simulation VeriStand for a target of VXWorks still?

Using the channel of the flaws with the reading of data

Is it possible to substitute a model output when I want real data playback using the stim profile editor? I understand how to use the flaws of the stim profile editor to replace an unique to a single value output channel, but is there a way to "fault

I need to display the CPU load of the controller under Veristand real-time on a copycat.

But one did not find a canal system (or equivalent) with these data. I have a controller with 8 processor cores (RMC8355), so I need to have the CPU 8 charges. Does anyone have a solution? Thank you

Addition of channels of memory using the API VeriStand reflection

I'm in the process of VS API allows you to add folders and channels the reflective memory of an existing system definition file section.  I can't see the channels and the existing folders or add new ones.  I have enclosed a snipit of code and code. 

Customized online device synchronization

Hello In one of our projects, we must pay special attention to synchronization. There are several custom devices (CD) that need to work together in a deterministic way. The question is: is at - it a way to ensure that the order of execution of the pa

Why Veristand so long to load? !!

Hi, I use VS 2011 SP1 on some hearts Intel Xeon 4 3, 2 GHz with 8 GB of RAM running Windows 7 64 bit PC. When I run VS2011 SP1, it takes 1m30s before the splashscreen is displayed. What can be the causes of this slow start?

Write to channel outside custom device

Hi all I am writing a custom device to control some aspects of my definition of system (more specifically another device custom).  I can't solve this problem because I can't find a way to write about a VeriStand channel located outside my custom devi

After the installation of TS 2012 - stop time about 16 minutes.

Problem after that installation of LabVIEW and TestStand will take about 16 minutes to turn off my laptop. Problem may be in TestStand 2012, see below. Lenovo laptop T520 Intel i7 processor 64-bit with Service Pack 1 Windows 7 Enterprice. How to inst

TestStand TypePalette

Hello! I have Veristand 2011 and 2012 TestStand. I want to add type VeriStand step to TestStand. I found this article: http://digital.NI.com/public.nsf/allkb/6DF9084839F471B7862576420068DC78 I though that a range of type has been created for veristan

Error when opening Veristand workspace

The attached dialog box appears when I open the screen of the workspace in the Project Explorer. When I click 'OK' to open the workspace and there seems not to be a problem, but it's always very disconcerting. Anyone know how to fix this error? Thank

VeriStand exe 'cannot open resource files."

VeriStand exe gives following error "Cannot open files from resources." and never begins to open.  It worked yesterday, but not today.  I have install DAQmx 9.6 and restarted my PC but that's all.  I tried to remove the VS ini file, no luck. Thanks i

RefNum of control in a custom device

I currently develop a device custom Veristand 2011 with Labview 2011. It is an Inline model. During initialization (and only in the initialization stage), I'm trying to list recursively all the controls within a Cluster (which represents a data struc

Veristand does co with target rt (pxi) and simulink simulation

Veristand supports simulation of co with target RT (pxi) and simulink MDL... If he is well wanted to share me partners implementation document (Note: we have already implemented .dll depending on model)

race model slightly differently in Veristand and Simulink

Hello I have a model containing a c s-function code. The model works well in Simulink, where the s function is also compiled to a mexw32. Then a dll is generated for Veristand 2011 using RTW and the veristand.tlc. Veristand, the results are the same

departure fom LabVIEW VeriStand

Hey guys,. I installed VeriStand a few days ago and now I would like to connect LabVIEW and VeriStand. I already explored how to run a profile of stimulus in an open VeriStand workspace to a LabVIEW VI. Now I would like to open & run the workspace (l

XCP and CCP Master add-on for NI VeriStand feedback.

Please use this thread for questions and comments on XCP and CCP Master add-on for NI VeriStand.