NI Software

Digital Test on VAL("") failure

The following will show how to cause a failure on a digital Test that contains a number not valid. In the post to your message box Expression: Val(Parameters.EnteredData,Locals.ValidNumber), Parameters.EnteredData=(Local.ValidNumber?Parameters.Entere

active enum entries, enums disabled in control and state machine accessibility

Background: I have an enum of entry that can be anything. In the vi, some enum States are 'disabled '. The enum led a state machine that defines the output. Question: If an entry corresponds to a "off State" it will create an exit?

I would like the encoder of data as well as the duration of treatment in a table

Hello I want to draw my value encoder of data as well as the duration of treatment simultaneously in a table by getting data in real time. Please help me with solutions or ideas.

How to with Labview startup window hidden when Teststand start loading

I have Teststand development enviroment and Labview development environment installed on my computer, my use of Labview teststand adapter applications. It is every time when I start the application being Teststand, Labview, window pop auto-start - up

Re: Convert please LabVIEW 14 to 13

Please convert from 2014 to 2013

Select VIEW tab is programmatically

Is it possible to select the VIEW tab, using a script? For example if the end user has a different tab selected in DIAdem (for example, the BROWSER or SCRIPT tab) the script selects the VIEW tab. Thank you

In 2013 TestStand, reportgen_html.seq, flow of data transfer

Hi, guys. I want to know the effect of each step of the sequence, but I do not understand step > AddStionID > Expression, for example below: I want to find where are set Locals.HeaderNameTagStart, Locals.HeaderValueTagStart, and so on. Based on the R

Value pairs

Hello! Invite please, if you can programmatically create compliance fumes graphic value 3D (Position - value) pairs. Or probably do that manually through 3D graphics properties?

I didn't event structure in my range of function

I didn't event structure in my palette of function I have to do?

Boolean text disappeared after the creation of the exe

Hello!!! Deploy an exe of a National Instruments touch panel touch panel. The exe contains a value Boolean LED indicator which is supposed to is set to display the Boolean text (multiple string function is also checked). However this function does no

Determine the number of serial port

I need to test my Board on 3 PC randomly. Whenever I connect the jury that happens the number of serial port as "com 18. Now, the number of Compote I use is 40. Although I am not any other USB connection. Although I update, I always get data only if

Path table

The problem I have is with array of paths. I included a folder zipped a few directories with a vi that I use to retrieve information in the records. The vi continues his return two cells with empty path no reason I can think. I tried several solution

Bug in LV? Confused: The property Exec.State to a closed vi?

I'm a bit confused by the Exec.State property:Try to find out the status of a VI, I use a loop constantly running in a Spy.vi to get the FP. Open the status and the spy VI Exec.state, as shown in the example below.Works very well. Except during the c

Datasocket bug in Win2K - constantly updated

= OVERVIEW =. I have a simple Datasocket system which produces a very strange problem on Win2K After a variable duration (from 30 seconds to 30 minutes), the player datasocket simply stop receiving updates of the writer. The system features a base Wr